FASCINATION ABOUT DP50RB

Fascination About Dp50rb

Fascination About Dp50rb

Blog Article

The consumer is just not allowed to open up the handles and panel with the process, neither Observe: product disassemble is permitted. To make sure the system efficiency and safety, only Mindray engineers or engineers authorized by Mindray can conduct maintenance.

.. Web site 161 The indicator within the printer Mistakes take place if the adapter turns orange, plus the printing printer adapter runs. Disconnect and join the fails. electric power adapter, electric power to the printer adapter all over again, and verify whether the printing is regular soon after 1 moment. Web site 163: Electrical Security Inspection

Click Agree and Carry on to just accept cookies and go directly to the site or click on More Information to determine in-depth descriptions of the categories of cookies and choose regardless of whether to simply accept sure cookies even though on the positioning.

Observe: Ensure that you could pull out and drive into your IO board sockets vertically when pulling out and assembling the IO board assembly within the posture in the cope with. Get rid of panhead screws with washers M3X6 (4) used to safe the IO board, and then you can take out the IO board. Web site 116 Take away panhead screws with washers (2 M3X6) that are preset on the key device, acquire out the upper baffle and afterwards pull out two cables connecting the principle board to the power module assembly.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Perform: Within the back again-conclusion of the most crucial board, a Exclusive keep an eye on IC is utilised to monitor sign voltages  and clock battery electrical power which are offered to the most crucial board by the most crucial device box electrical power offer module.

General performance Test five.5.one Test Procedure Resolution Detection depth Geometric Position Accuracy Blackout area check Record the exam photos 5.5.two Test Content material The impression utilized Here's only for reference, persist with the impression effect in the actual NOTE: condition. Needs: Display: set the contrast and brightness within the clinical software price (or maybe the default status) Operation setting: dark area, simulating the scientific software natural environment. Website page seventy six In affliction the transverse resolution screening targets are horizontally displayed, document the minimum distance of two targets that can be Plainly regarded. Repeat the operation earlier mentioned to the transverse resolution screening targets at other depths. As demonstrated in figure below. Axial resolution ... Website page 77 When utilizing the convex probe, hold the transverse resolution screening targets to notice: be exhibited near the midline. When employing a linear probe with steer function, usually do not activate the steer function when execute the transverse resolution check. Zoom from the area the place the targets Positioned if necessary. The diameter of the goal position at a certain depth is equivalent into the transverse resolution within the depth. Webpage seventy eight five.

Discover greater diagnostic facts by means of extended see of your anatomical framework on all linear probes

NOTE: In advance of uploading the log, be certain the ultrasound process continues to be linked Dp50rb login to community, normally, the process could warn “couldn't hook up with server” The server (smtp.

After replacing the CPU module, critical file has to be produced Yet again according to the new MAC handle and prepared into HDD on the device. Or else, the configuration perform in the merchandise might be misplaced. After eliminating the CPU module, Remove panhead screws with washers (12 M3X6) fastened on the main unit box, you might take off the board. Web page 118 Figure 8-29 Disassemble the Control Panel Assembly (one) Keep the higher edge of user interface assembly, and open up the control panel. Figure eight-thirty Disassemble the Control Panel Assembly (two) After eradicating just one countersunk head self-tapping screw PT3X10 fastened to the control panel and consider out the plug on the keyboard and the key device connecting cables, you could remove the user interface assembly.

Return on the technique preset interface. The choice status adjustments into Uninstalled. The uninstalling perform is exceptional to inside buyers.

This guide may referring to facts safeguarded by copyright or patents and will not Express any license underneath the patent legal rights or copyright of Mindray, or of Other folks. Page 9: Statement

Lower off cable ties connecting the leading device on the Show by diagonal reducing pliers, and afterwards pull out the corresponding cable plugs.

Your tool for further biopsy: allowing changes towards the scan line to achieve much better visibility in the needle, nerves and tiny vessels, guaranteeing the continuity of all info.

Report this page